Resistive |
Parameter |
3.5 |
4.3 |
5.7 |
7.0 |
Notes |
type |
res |
res |
res |
res |
|
enable |
y |
y |
y |
y |
enable touch keys globally with
y or n |
samples |
- |
12 |
12
|
22 |
define the number of touch
samples per interrupt. |
debounce |
- |
25 |
30 |
25 |
define the time period between
each sampling period. |
accuracy |
- |
50
|
14 |
12 |
define the 0.25 pixel accuracy
of the samples. |
inactive |
1000 |
1000 |
1000 |
1000 |
time in milliseconds (0=off) |
To increase the
sensitivity set samples = low number e.g. 3
This may only be suitable for buttons which are larger than 80x80 pixels
|
3.5 |
4.3 |
5.7 |
7.0 |
|
Code |
|
simple program to help test touch setup |
Projective Capacitive |
Parameter |
4.3 |
5.7 |
7.0 |
Notes |
type |
cap |
cap |
cap |
|
width |
272 |
480 |
480 |
default to height of display
|
height |
480 |
640 |
800 |
default to width of display
|
xnum |
16 |
16 |
16 |
number of X electrodes
|
ynum |
14 |
14 |
14 |
number of Y electrodes
|
gain |
0 |
0 |
0 |
gain of ADC |
threshold |
25 |
25 |
25 |
|
debounce |
3 |
3 |
3 |
|
address |
75 |
75 |
75 |
I2C address of controller |
inactive
|
1000 |
1000 |
1000 |
time in milliseconds (0=off) |
filterlevel
|
1 |
1 |
1 |
level of filtering applied 0-15 |
filterlimit
|
4 |
4 |
4 |
maximum filter limit 0-7 |
filterenable |
Y |
Y |
Y |
enable filtering Y/N |
switch
|
Y |
Y |
Y |
switch X and Y electrodes |
invertx |
Y |
Y |
Y |
invert the order of the X
electrodes |
inverty |
N |
N |
N |
invert the order of the Y
electrodes |
enable |
Y |
Y |
Y |
enable touch keys globally with
y or n |
|
4.3 |
5.7 |
7.0 |
|
Code |
|
|
|
simple program to help test touch setup |
v49.37 Added ability to specify mxt224 object data using Txx as
the parameter name :-
ie T9 = "15,00,02,11";
Added separate setup code for all mxt224 variants
(mxt224v1,mxt224v2,mxt224Ev1,mxt224Ev2)
Added RESET(TOUCH); for projective capacitive touch
Immediate/Contact Capacitive |
Parameter |
7.0 |
Notes |
type |
ICT
CCT |
part number suffix of
module |
enable |
Y |
enable touch keys globally with
y or n |
inactive |
1000 |
time in milliseconds (0=off) |
Type= part number
suffix of module ie TU800x480C-K612A1U-CCT would use type=cct;
Metallised - (works with
firmware v49.56.5+) |
Parameter |
4.3 |
5.7 |
7.0 |
Notes |
type |
cap_dbg |
cap_dbg |
cap_dbg |
|
width |
480 |
620 |
800 |
default to width of display |
height |
272 |
460 |
480 |
default to height of display |
xnum |
16 |
15 |
19 |
number of X electrodes |
ynum |
14 |
14 |
14 |
number of Y electrodes |
gain |
2 |
2 |
2 |
gain of ADC |
threshold |
8 |
8 |
8 |
decrease value for thicker front
panel |
debounce |
3 |
3 |
3 |
decrease for faster response |
switch |
n |
n |
n |
switch X and Y electrodes |
invertx |
y |
y |
y |
invert the order of the X
electrodes |
inverty |
n |
n |
n |
invert the order of the Y
electrodes |
ycorr |
- |
- |
20 |
|
ymid |
- |
- |
200 |
|
Firmware version v49.56.6+ only requires the
type and threshold values all other parameters will be ignored
|