ELECTRO-STATIC DISCHARGE (Method IEC 6100-4-2):
The module was powered up running the demo sequence on the test table. There
it was exposed to contact and air discharges applied to the ribbon cable
across the module face, the horizontal conductive plane under the module, and
the vertical conductive plane.

|
|
TU480 results |
Observation |
Contact Discharge |
Air Discharge |
|
Planes (1&2) |
Ribbon (3) |
Planes (1&2) |
Ribbon (3) |
Lowest voltage discharged |
1kV |
1kV |
2kV |
2kV |
Temporary spurious ON/OFF of pixels |
9kV |
None |
None |
None |
Module reset |
None |
2kV |
None |
None |
Permanent damage |
None |
None |
None |
None |
Highest voltage discharged |
9kV |
2kV |
10kV |
10kV |
|
TU640 results |
Observation |
Contact Discharge |
Air Discharge |
|
Planes (1&2) |
Ribbon (3) |
Planes (1&2) |
Ribbon (3) |
Lowest voltage discharged |
1kV |
1kV |
8kV |
8kV |
Temporary spurious ON/OFF of pixels |
6kV |
1kV |
9kV |
10kV |
Module reset |
None |
4kV |
None |
None |
Permanent damage |
None |
None |
None |
None |
Highest voltage discharged |
9kV |
4kV |
10kV |
10kV |
|
TU800 results |
Observation |
Contact Discharge |
Air Discharge |
|
Planes (1&2) |
Ribbon (3) |
Planes (1&2) |
Ribbon (3) |
Lowest voltage discharged |
1kV |
1kV |
2kV |
2kV |
Temporary spurious ON/OFF of pixels |
6kV |
4kV |
None |
None |
Module reset |
None |
6kV |
None |
None |
Permanent damage |
None |
None |
None |
None |
Highest voltage discharged |
9kV |
6kV |
10kV |
10k |
|